- When spray drying a biopharmaceutical(BP), its integrity should be maintained upon processing.
- The integrity of a biopharmaceutical can be determined by monitoring its conformational stability through its melting Temperature (Tm) shift.
- Differential Scanning Calorimetry (DSC) and Dynamic Light Scattering (DLS) are two analytical techniques usually employed to determine Tm
However,
- these require large sample volumes at high concentrations
- are time-consuming
Differential Scanning Fluorimetry might be an alternative
- allows simultaneous screening of more than one sample;
- at low concentration requirements.
Convenient when dealing with expensive molecules such as biopharmaceuticals!